ANS Việt Nam là công ty XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng“Thiết bị điện, Điện công nghiệp, Điện tự động”
QUÍ KHÁCH CÓ NHU CẦU VUI LÒNG LIÊN HỆ:
ĐẠI LÝ CHÍNH THỨC VAISALA | VAISALA VIETNAM | BỘ CHUYỂN ĐỔI NHIỆT ĐỘ VÀ ĐỘ ẨM VAISALA
List code:
Vaisala Vietnam | Code: HMT330 5N0B021GCAF100A01CGCAA1 |
Humidity and Temperature Transmitter | |
Transmitter type: HMT335 for high temperatures; Probe cables: Probe 10m +180C,0-10MPa; No Additional temperature probe, No Display; Calculations: Cod RH+T+Td+a+Tw+x+h+pws; Power supply: Universal AC-Power (100...240VAC); Signal output: 4...20mA | |
Analog output signals for Ch1: Tw (0...+100C); Analog output signals for Ch2: Temperature Range -20...+60C; No Analog output signals for Ch3; No Module option for module slot 1&2; Cable bushings: Sealed Cable Gland M20x1.5; No Installation Kit; Humidity sensor: General purpose HUMICAP180; Sensor protection: Sintered Filter AISI 316L HM47280; Installation kit for probe: Mounting Flange for D13.5mm Probe; No Accessories; No Calibration Contract ISO9001 Calibration; No Maintenance Contract | |
Vaisala Vietnam | Model: HMT330-7S1D011BXAA100A4LCQBAA1 |
HMT330 Humidity and Temperature Transmitter | |
Humidity sensor: Heated Composite sensor Humicap H2O2 Sensor with chemical purge default; Sensor protection: Sintered Filter AISI 316L HM47280; Installation kit for probe: Customer has to choose “Swagelok for 12mm Probe 1/2" NPT Thread” or“Swagelok for 6mm probe 1/8" NPT Thread” | |
No Accessories, No Calibration Contract ISO9001 Calibration | |
Vaisala Vietnam | Model: HMD60T |
Temperature Transmitter, 2-wire | |
Vaisala Vietnam | Model: HMD60U |
Humidity Transmitter, 2-wire | |
Vaisala Vietnam | Model: HM41 |
Hand-Held Humidity and Temperature meter Standard Probe HM41 | |
Vaisala Vietnam | Model: HMT310-3A5A1BCK14BBDA1B2 |
Humidity and Temperature Transmitter HMT310-3A5A1BCK14BBDA1B2; Probe code: HMT313; Parameters: Code RH+T | |
Mounting Plate: Wall Plate with Flange; Power supply: Standard (24 VDC); Signal output: Analog Output (CH1+CH2) Output 4...20mA | |
Analog output signals for Ch1: Channel 1 RH (0...100%RH) | |
Analog output signals for Ch2: Channel 2 T (Range See Below) | |
Analog output range for temperature: Temperature Range 0...+100C | |
Cable connector: Connection Cable 5m 8 pin M12 Female, Black | |
Probe type: HMP303 Probe 2m; Humidity sensor type: composite sensor with chemical purge default HUMICAP180RC | |
Sensor protection in probe: PPS Grid with Steel Netting | |
Installation kit: Duct Installation Kit For HMT333 and HMT337 | |
Calibration Certificate At Room Temperature | |
Vaisala Vietnam | Code: HMP360 4E2A302 |
HMP360 Humidity and Temperature Transmitter series Probes; Probe type: HMP364 for pressurized processes; Probe length and probe cable length : Hmp364 2m Cable; Sensor type: Humicap 180l2; Reserved for future us; Sensor protection : Sintered Filter AISI 316L HM47280; No Installation kit for probe; Ex Certification ATEX/VTT |